Contec 3 channel ECG machine can collects12-lead ECG signal simultaneously and printing ECG waveform with thermal printing system. Contec 3 channel ECG machine comes with unique features such as recording and displaying ECG waveform with manual or auto mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management.
Specifications Of Contec ECG machine 3 Channel:
Product Name | Contec 300G 3 Channel ECG Machine |
Brand | Contec |
Model | 300G |
ECG Type | 3 Channel ECG with interpretation |
ECG Channel | 3 Channel |
ECG Storage | Up to 1000 patent's data |
ECG Record mode | Auto and Manual |
Display | YES |
80 mm(Width) ECG paper | |
Battery | Built-in Rechargeable Battery |
Battery Backup | Approx 1.5 hours with continuous printing |
Waterproof Degree | IPX0 |
In the BOX | Contec 3 channel ECG machine, ECG paper, ECG cable, power cable, 1 set of clamp electrodes, 1 set of blub electrodes, earthing cable, user guide |
Other Important features of Contec 3 Channel ECG machine :
- Input mode: floating and defibrillation protection
- Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
- CMRR: >60dB, >100dB (add filter)
- Time constant:≥ 3.2s
- Patient leak current: <10µA
- Calibration voltage: 1mV
- Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
- Noise level: <15µVp-p
- Input circuit current: ≤50nA
- Input impedance: ≥50MΩ
- Sampling accuracy: 12-bit
- Safety classification: class I, type CF and defibrillation-proof applied part
- Recording mode: thermal printing system
- Auto record: set record according to auto-record format and mode, automatically switching leads, measuring and analyzing.
- Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
- Manual record: set record according to record format, manually switching leads.
- Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
- Paper size: 80 mm(W)×20 m(L)
- Sampling frequency: 1000Hz
- EMG interference filter: 25Hz/35Hz (-3dB)
- Power frequency filter: AC 50Hz/60Hz(-20dB)
- Paper speed:
- Auto: 25, 50 mm/s, ±5%
- Rhythm: 25, 50 mm/s, ±5%
- Manual: 5, 6.25, 10, 12.5, 25, 50 mm/s, ±5%
- Power supply:AC: 100V~240V(50/60Hz), DC: 7.4V/3500mAh, rechargeable lithium battery
- Fuse specification: two AC time lag fuse(φ5×20 mm), T1.6AL250V
- Waterproof degree: IPX0
- Working mode: continuous working
- 1 no. Of ECG Cable
- 1 Set of Bulb Electrode
- 1 Set Clamp Electrode
- 1 no. of Power Cable
- 1 no. of Earthing Cable
- 1 ECG paper roll
- User Mannual
- 1 Years
- 3 Channel
- Auto Mode ,
- Manual